Table 2 Summary of selected resin separation tests including treatment steps and outcome

From: Evaluating ion exchange resin efficiency and oxidative capacity for the separation of uranium(IV) and uranium(VI)

Resin Column Type Oxic or anoxic conditions Ti(III) treatment Initial [Utot] (μM)a Utot Recovered (%)a Initial U(IV) (%) Initial U(VI) (%) Recovered as U(IV) (%)b Recovered as U(VI) (%)b
Bio-Rad AG1x8 prefilled Bio-Rad Poly-prep Oxic No 2.1 72 0 100 0 100
Bio-Rad AG1x8 prefilled Bio-Rad Poly-prep Oxic No 22.2 86 0 100 0 100
Bio-Rad AG1x8 powder Bio-Rad Poly-prep Oxic No 2.1 92 0 100 0 100
Dowex 1x8 powder Bio-Rad Poly-prep Oxic No 2.1 100 0 100 0 100
Dowex 1x8 powder Pierce polystyrene Oxic No 2.1 100 0 100 0 100
Bio-Rad AG1x8 prefilled Bio-Rad Poly-prep Anoxic No 2.1 81 36 64 0 100
Dowex 1x8 powder Pierce polystyrene Anoxic No 8.7 100 98 2 86 14
Dowex 1x8 powder Pierce polystyrene Anoxic Yes 8.7 100 98 2 98 2
Dowex 1x8 powder Pierce polystyrene Anoxic Yes 1.8 100 0 100 0 100
Dowex 1x8 powder Pierce polystyrene Anoxic Yes 2.8 100 100 0 100 0
Dowex 1x8 powder Pierce polystyrene Anoxic Yes 2.1 100 10 90 11 89
Dowex 1x8 powder Pierce polystyrene Anoxic Yes 1.8 100 48 52 47 53
  1. a. 1 mL of uranium solution added to resin, uncertainty in recovered Utot was 3%.
  2. b. Uncertainty in speciation recovery was 1%.