Skip to main content

Table 2 Specification of the electronic weather station

From: An automatic system for continuous monitoring of CO2, H2S, SO2and meteorological parameters in the atmosphere of volcanic areas

Internal temperature

 

   Measuring range

0 to 50 °C

   Accuracy

± 1 °C

   Resolution

0.1°C typical

External temperature

 

   Measuring range

-40 to 60 °C

   Accuracy

± 2 °C

   Resolution

0.1 °C typical

Relative humidity

 

   Measuring range

10 to 97% RH

   Accuracy (at temp, range 15 to 40 °C)

± 5% RH

   Resolution

1% RH

Barometric pressure

 

   Measuring range

795 to 1050 mbar

   Accuracy (at temp, range 0 to 50 °C)

± 7 mbar

   Resolution

1 mbar

Wind speed

 

   Measuring range

0 to 56 m s-1

   Accuracy (at temp, range -20 to 60 °C)

--

(1) range 2 to 10 ms-1

± lms-1

(2) range 10 to 56 m s-1

± 10%

   Resolution

0.2 m s-1

Wind direction

 

   Measuring range

0 to 359°

   Accuracy

± 8°

   Resolution

Rainfall

 

   Daily and cumulative measuring range

0 to 9999 mm

   Rainfall rate measuring range

0 to 998 mm h-1