Skip to main content

Table 5 Measured redox potential Eh (mV), referenced to standard hydrogen electrode, in different treatments

From: Effect of reducing groundwater on the retardation of redox-sensitive radionuclides

Test ID

Alluvium/J-13

Devitrified tuff/J-13

Zeolitic tuff/TCU

Carbonate/LCA

 

J-13 Controla

Blank

Sorption

Blank

Sorption

Control

Blank

Sorption

Control

Blank

Sorption

A

362 ± 13

368 ± 4.8

312 ± 9.9

341 ± 11

338 ± 10

357 ± 6.1

340 ± 5.7

319 ± 5.7

345 ± 4.5

353 ± 1.5

335 ± 4.2

B

207 ± 0.14

205 ± 0.64

206 ± 2.0

201 ± 2.4

203 ± 2.0

186 ± 0.215

191 ± 0.35

187 ± 1.2

195 ± 2.8

204 ± 0.4

195 ± 0.4

C

(-50) ± 1.0

(-27) ± 2.8

(-31) ± 1.1

(-41) ± 0.21

(-22) ± 0.31

29.4 ± 0.64

(-8.3) ± 0.21

(-25) ± 0.36

(-35) ± 0.64

(-34) ± 1.6

(-22) ± 1.4

D

(-55) ± 9.9

(-83) ± 0.07

(-82) ± 1.0

(-82) ± 0.78

(-70) ± 1.4

(-98) ± 1.3

(-102) ± 2.8

(-95) ± 0.60

(-54) ± 2.5

(-90) ± 0.14

(-82) ± 0.67

E

(-50) ± 1.0

(-47) ± 1.8

(-63) ± 6.5

(-56) ± 2.4

(-59) ± 2.7

(-52) ± 0.78

(-69) ± 0.21

(-73) ± 0.38

(-52) ± 0.14

(-59) ± 2.2

(-68) ± 0.85

  1. a The alluvium/J-13 control is also applicable for devitrified tuff/J-13 treatment.